APL-UW Home

Jobs
About
Campus Map
Contact
Privacy
Intranet

Vera Khokhlova

Senior Principal Engineer

Email

verak2@uw.edu

Phone

206-221-6585

Education

M.S. Physics, Moscow State University, 1986

Ph.D. Acoustics, Moscow State University, 1991

Videos

Ultrasonic tweezers: Technology to lift and steer solid objects in a living body

In a recent paper, a CIMU team describes successful experiments to manipulate a solid object within a living body with ultrasound beams transmitted through the skin.

More Info

15 Jul 2020

A collaborative, international research teams developed and tuned an ultrasound transducer to create vortex shaped beams that can trap, grab, levitate, and move in three dimensions mm-scale objects. The team is working to apply this technology to their all-in-one kidney stone treatment system that, in clinical trials, uses ultrasound to non-invasively break, erode, and move stones and stone fragments out of the kidney so that they may pass naturally from the body.

Mechanical Tissue Ablation with Focused Ultrasound

An experimental noninvasive surgery method uses nonlinear ultrasound pulses to liquefy tissue at remote target sites within a small focal region without damaging intervening tissues. A multi-institution, international team led by CIMU researchers is applying the method to the focal treatment of prostate tumors.

More Info

19 Mar 2020

Boiling histotripsy utilizes sequences of millisecond-duration HIFU pulses with high-amplitude shocks that form at the focus by nonlinear propagation effects. Due to strong attenuation of the ultrasound energy at the shocks, these nonlinear waves rapidly heat tissue and generate millimeter-sized boiling bubbles at the focus within each pulse. Then the further interaction of subsequent shocks with the vapor cavity causes tissue disintegration into subcellular debris through the acoustic atomization mechanism.

The method was proposed at APL-UW in collaboration with Moscow State University (Russia) and now is being evaluated for various clinical applications. It has particular promise because of its important clinical advantages: the treatment of tissue volumes can be accelerated while sparing adjacent structures and not injuring intervening tissues; it generates precisely controlled mechanical lesions with sharp margins; the method can be implemented in existing clinical systems; and it can be used with real-time ultrasound imaging for targeting, guidance, and evaluation of outcomes. In addition, compared to thermal ablation, BH may lead to faster resorption of the liquefied lesion contents.

Characterizing Medical Ultrasound Sources and Fields

For every medical ultrasound transducer it's important to characterize the field it creates, whether for safety of imaging or efficacy of therapy. CIMU researchers measure a 2D acoustic pressure distribution in the beam emanating from the source transducer and then reconstruct mathematically the exact field on the surface of the transducer and in the entire 3D space.

11 Sep 2017

Publications

2000-present and while at APL-UW

A fully populated transrectal array for boiling histotripsy ablation of the prostate

Rosnitskiy, P.B., G.P.L. Thomas, G.L. Lee, V.A. Khokhlova, O.A. Sapozhnikov, G.R. Schade, K.P. Morrison, F. Chaves, and T.D. Khokhlova, "A fully populated transrectal array for boiling histotripsy ablation of the prostate," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 72, 1336-1351, doi:10.1109/TUFFC.2025.3596780, 2025.

More Info

1 Oct 2025

The endorectal ultrasound (US)-guided thermal ablation of prostate cancer (PCa) using high-intensity focused ultrasound (HIFU) is a widely used focal intervention. While generally safe and effective, it is not without challenges associated with heat diffusion and prefocal heating, which has spurred interest toward nonthermal and mechanical HIFU ablation regimes. Another challenge is the necessity to mechanically translate the HIFU transducer-commonly single-element or annular array-for volumetric treatments, which results in target shifts and transducer position readjustment. The 2-D arrays would address this problem, but their design is challenging in a small form factor. The element pattern must be tightly packed and aperiodic to maximize the active surface area and to suppress grating lobes, respectively. Here, we report on the design, fabrication, and performance evaluation of a 1.5-MHz 128-element transrectal HIFU array driven by Verasonics system capable of mechanical tissue ablation via boiling histotripsy (BH) under real-time coaxial US imaging guidance. A recently developed method for designing randomized, fully populated mosaic arrays was used to create the element pattern. The measured focus steering ranges of the fabricated array were 26 mm axially and 12 mm laterally in the BH regime, with driving voltage compensation by less than 43% and no grating lobe formation. Stress tests with a five-element prototype confirmed safe operating voltage of 850-V peak-to-peak, corresponding to the acoustic intensity of 542 W/cm(2) at the array surface. The array integrated with a 128-element US imaging probe driven by the same Verasonics system was successfully used to produce volumetric BH lesions in polyacrylamide (PAA) tissue-mimicking phantoms.

xDDx: A numerical toolbox for ultrasound transducer characterization and design with acoustic holography

Rosnitskiy, P.B., O.A. Sapozhnikov, V.A. Khokhlova, W. Kreider, S.A. Tsysar, G.P.L. Thomas, K. Contreras, and T.D. Khokhlova, "xDDx: A numerical toolbox for ultrasound transducer characterization and design with acoustic holography," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 72, 564-580, doi:10.1109/TUFFC.2025.3542405, 2025.

More Info

1 May 2025

Transient acoustic holography is a useful technique for characterization of ultrasound transducers. It involves hydrophone measurements of the 2-D distribution of acoustic pressure waveforms in a transverse plane in front of the transducer—a hologram—and subsequent numerical forward projection (FP) or backward projection of the ultrasound field. This approach enables full spatiotemporal reconstruction of the acoustic field, including the vibrational velocity at the transducer surface. This allows identification of transducer defects as well as structural details of the radiated acoustic field such as sidelobes and hot spots. However, numerical projections may be time-consuming ( 1010 – 1011 operations with complex exponents). Moreover, backprojection from the measurement plane to the transducer surface is sensitive to misalignment between the axes of the positioning system and the axes associated with the transducer. This article presents an open-access transducer characterization toolbox for use in MATLAB or Octave on Windows computers (https://github.com/pavrosni/xDDx/releases). The core algorithm is based on the Rayleigh integral implemented in C++ executables for graphics and central processing units (GPUs and CPUs). The toolbox includes an automated procedure for correcting axes misalignments to optimize the visualization of transducer surface vibrations. Beyond using measured holograms, the toolbox can also simulate the fields radiated by user-defined transducers. Measurements from two focused 1.25-MHz 12-element sector transducers (apertures of 87 mm and focal distances of 65 and 87 mm) were used with the toolbox for demonstration purposes. Simulation speed tests for different computational devices showed a range of 0.2 s – 3 min for GPUs and 1.6 s – 57 min for CPUs.

Synthesized acoustic holography: A method to evaluate steering and focusing performance of ultrasound arrays

Williams, R.P., W. Kreider, F.A. Nartov, M.M. Karzova, V.A. Khokhlova, O.A. Sapozhnikov, and T.D. Khokhlova, "Synthesized acoustic holography: A method to evaluate steering and focusing performance of ultrasound arrays," J. Acoust. Soc. Am., 157, 2750-2762, doi:10.1121/10.0036225, 2025.

More Info

11 Apr 2025

Acoustic holography is a commonly used tool to characterize the three-dimensional acoustic fields and the vibration patterns of ultrasound (US) transducers and arrays. It involves recording the pressure distribution over a transverse plane in front of the transducer via a two-dimensional hydrophone scan, and subsequent forward or backward field projection. For multi-element arrays capable of electronic focus steering, a separate hologram is needed to describe each beam configuration of interest. Since medical US arrays commonly use tens to hundreds of beam configurations, their characterization is very time consuming. Here, we show that holograms for the field of each array element can be recorded with a single hydrophone scan by pulsing the elements sequentially at each location. This approach was validated using a 1 MHz 64-element diagnostic-therapeutic linear array. Holograms of each element combined with backpropagation to the array surface revealed the variability of vibration patterns and crosstalk between channels and elements. Electronically steered beam configurations resulting from boundary conditions synthesized from elemental holograms and directly measured holograms were found to be in excellent agreement. The results demonstrate the method's potential in detecting defects and other nonideal array behavior and in rapid and accurate characterization of all relevant beam configurations.

More Publications

Inventions

Boiling histotripsy methods and systems for uniform volumetric ablation of an object by high-intensity focused ultrasound waves with shocks

Patent #12,157,018

Patent Number: 12,157,018

Vera Khokhlova, Mike Bailey, Wayne Kreider, Oleg Sapozhnikov, Yak-Nam Wang

More Info

Patent

3 Dec 2024

An example method includes generating an acoustic ultrasound wave that is focused at a focal point. The method further includes sequentially directing the focal point upon distinct portions of an object to form respective shock waves at the distinct portions of the object. The method further includes, via the respective shock waves, causing the distinct portions of the object to boil and form respective vapor cavities. The method further includes causing substantially uniform ablation of a region of the object that comprises the distinct portions. The substantially uniform ablation is caused via interaction of the respective shock waves with the respective vapor cavities. An example ablation system and an example non-transitory computer-readable medium, both related to the example method, are also disclosed.

Transrectal Ultrasound Probe for Boiling Histotripsy Ablation of Prostate, and Associated Systems and Methods

Inventors: V. Khokhlova, P. Rosnitskiy (Seattle), P.V. Yuldashev (Moscow), T.D. Khokhlova (Seattle), O. Sapozhnikov, and G.R. Schade (Seattle)

Patent Number: 11,896,853

Vera Khokhlova, Oleg Sapozhnikov

Patent

13 Feb 2024

High Intensity Focused Ultrasound Systems for Treating Tissue

Inventors: Y.-N. Wang, M.R. Bailey, T.D. Khokhlova (Seattle), W. Kreider, A.D. Maxwell, G.R. Schade (Seattle), and V.A. Khokhlova

Patent Number: 11,857,813

Yak-Nam Wang, Mike Bailey, Wayne Kreider, Adam Maxwell, Vera Khokhlova

Patent

2 Jan 2024

More Inventions

Acoustics Air-Sea Interaction & Remote Sensing Center for Environmental & Information Systems Center for Industrial & Medical Ultrasound Electronic & Photonic Systems Ocean Engineering Ocean Physics Polar Science Center
Close

 

Close